Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Aksu, Feyza" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Küçük Resim Yok
    Öğe
    Comparative Analysis of Conventional and Focused Data Augmentation Methods in Rib Fracture Detection in CT Images
    (Mdpi, 2025) Goktekin, Mehmet Cagri; Gul, Evrim; Aksu, Feyza; Gul, Yeliz; Ozen, Metehan; Salik, Yusuf; Avci, Engin
    Background/Objectives: Rib fracture detection holds critical importance in the field of medical image processing. Methods: In this study, two different data augmentation methods, traditional data augmentation (Albumentations) and focused data augmentation (focused augmentation), were compared using computed tomography (CT) images for the detection of rib fractures on YOLOv8n, YOLOv8s, and YOLOv8m models. While the traditional data augmentation method applies general transformations to the entire image, the focused data augmentation method performs specific transformations by targeting only the fracture regions. Results: The model performance was evaluated using the Precision, Recall, mAP@50, and mAP@50-95 metrics. The findings revealed that the focused data augmentation method achieved superior performance in certain metrics. Specifically, analysis on the YOLOv8s model showed that the focused data augmentation method increased the mAP@50 value by 2.18%, reaching 0.9412, and improved the recall value for fracture detection by 5.70%, reaching 0.8766. On the other hand, the traditional data augmentation method achieved better results in overall precision metrics with the YOLOv8m model and provided a slight advantage in the mAP@50 value. Conclusions: The study indicates that focused data augmentation can contribute to achieving more reliable and accurate results in medical imaging applications.

| Malatya Turgut Özal Üniversitesi | Kütüphane | Açık Bilim Politikası | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Malatya Turgut Özal Üniversitesi, Malatya, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2026 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim