    Comparison of anterior chamber depth measurements of Nidek AL-Scan and Galilei Dual Scheimpflug Analyzer
    (Elsevier Science Bv, 2015) Dervisogullari, Mehmet Serdar; Totan, Yuksel; Guragac, Betul
    Purpose: We aimed to compare anterior chamber depth (ACD) measurements between the Nidek AL-Scan and the Galilei Dual Scheimpflug Analyzer. Setting: Turgut Ozal University Medical Faculty, Ankara, Turkey. Design: Prospective masked bilateral randomized study. Methods: Sixty-three individual patient eyes with normal ocular examination findings and no prior ocular surgery were analyzed. Paired two-tailed t-test was used to evaluate agreement between devices. Interobserver repeatability was evaluated in 22 patients using intraclass correlation coefficient (ICC) and Bland-Altman analysis. Results: The mean +/- standard deviation (+/- SD) ACD for Nidek and Galilei was 3.57 +/- 0.29 (range from 2.92 to 4.32) and 3.65 +/- 0.29 (range from 3.01 to 4.40), respectively. Comparing the two instruments using paired samples t-test, a statistically significant difference was found between the measurements obtained for ACD (P = 0). Two observers' intraclass correlation coefficients (ICC) were 0.996 for Nidek and 0.968 for Galilei. For Nidek, ACD mean difference was 0 mm (P < 0.001); 95% limits of agreement was from -0.05 to 0.05. For Galilei ACD mean difference was -0.01 mm (P < 0.001); 95% limits of agreement was from -0.14 to 0.12. The Galilei Dual Scheimpflug Analyzer measured longer ACD values than the Nidek AL-Scan. Conclusion: This comparative study showed that the difference in ACD between the measurements of the Nidek AL-Scan and the Galilei Dual Scheimpflug Analyzer was statistically significant but clinically it was negligible. Further studies are needed, especially on IOL calculation formulas that include ACD and its effect on postoperative spherical equivalent values. C) 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

| Malatya Turgut Özal Üniversitesi | Kütüphane | Açık Bilim Politikası | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Malatya Turgut Özal Üniversitesi, Malatya, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim