Examination Of Insert Ear Interaural Attenuation (Ia)Values In Audiological Evaluations

dc.contributor.authorGumus, Nebi Mustafa
dc.contributor.authorGumus, Merve
dc.contributor.authorUnsal, Selim
dc.contributor.authorYüksel, Mustafa T.
dc.contributor.authorGündüz, Mehmet
dc.date.accessioned2025-10-24T18:06:44Z
dc.date.available2025-10-24T18:06:44Z
dc.date.issued2016
dc.departmentMalatya Turgut Özal Üniversitesi
dc.description.abstractPurpose: The purpose of this study was to evaluate Interaural Attenuation (IA) in frequency base in the insert earphones that are used in audiological assessments. Methods: Thirty healthy subjects between 18-65 years of age (14 female and 16 male) participated in our study. Otoscopic examination was performed on all participants. Audiological evaluations were performed using the Interacoustics AC40 clinical audiometer and ER-3A insert earphones. IA value was calculated by subtracting good ear bone conduction hearing thresholds of the worst airway hearing threshold. Results: In our measuring for 0.125-8.0 kHz frequency were performed in our audiometry device separately for each frequency. IA amount in the results we found in 1000 Hz and below frequencies about 75-110 dB range avarage is 89±5dB, in above 1000 Hz frequencies in 50-95 dB range and avarage it is changed to 69±5dB. Conclusion: According to the obtained findings the quantity of melting in the transition between the ears are increasing with the insert earphones. The insert earphone should be beside supraaural earphone that is routinely used in clinics. Difficult masking applications due to the increase in the value of IA can be easily done with insert earphones © 2021 Elsevier B.V., All rights reserved.
dc.identifier.doi10.25011/CIM.V39I6.27507
dc.identifier.endpage85
dc.identifier.issn0147-958X
dc.identifier.issn1488-2353
dc.identifier.issue6
dc.identifier.pmid27917798
dc.identifier.scopus2-s2.0-85047593940
dc.identifier.scopusqualityQ2
dc.identifier.startpage82
dc.identifier.urihttps://doi.rog/10.25011/CIM.V39I6.27507
dc.identifier.urihttps://hdl.handle.net/20.500.12899/3179
dc.identifier.volume39
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherThe Canadian Society for Clinical Investigation
dc.relation.ispartofClinical and Investigative Medicine
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzScopus_20251023
dc.subjectadolescent
dc.subjectadult
dc.subjectaged
dc.subjectaudiology
dc.subjectdevices
dc.subjectear
dc.subjectfemale
dc.subjecthuman
dc.subjectmale
dc.subjectmiddle aged
dc.subjectnormal human
dc.subjectotoscopy
dc.subjectphysiology
dc.subjectprocedures
dc.subjectpure tone audiometry
dc.subjectyoung adult
dc.subjectAdolescent
dc.subjectAdult
dc.subjectAged
dc.subjectAudiology
dc.subjectAudiometry, Pure-Tone
dc.subjectEar
dc.subjectFemale
dc.subjectHealthy Volunteers
dc.subjectHumans
dc.subjectMale
dc.subjectMiddle Aged
dc.subjectOtoscopy
dc.subjectYoung Adult
dc.titleExamination Of Insert Ear Interaural Attenuation (Ia)Values In Audiological Evaluations
dc.typeArticle

Dosyalar